A/V J Type Power Conditioner and Battery Backup
Troubleshooting
Problem
Possible Cause
Corrective Action
The unit will not turn on.
The unit is not connected to utility power. Ensure that the unit is securely connected to 
a utility power outlet.
The internal battery is not connected.
Connect the battery.
The unit does not provide 
power during a utility power 
outage.
Ensure that essential equipment is not 
plugged into a 
S
URGE
 O
NLY
 outlet.
Disconnect equipment from the 
S
URGE
 
O
NLY
 outlet and re-connect to a Battery 
Backup outlet.
The unit is operating on 
battery power, while connected 
to utility power.
The plug has partially pulled out of the 
wall outlet, the wall outlet is no longer 
receiving utility power, or the circuit 
breaker has been tripped.
Ensure that the plug is fully inserted into 
the wall outlet. Ensure that the wall outlet is 
receiving utility power by checking it with 
another device.
The unit is performing an automatic self 
test.
No action is necessary.
The utility input voltage is out of range, 
the frequency is out of range, or the 
waveform is distorted.
Adjust the transfer voltage and sensitivity 
range.
The circuit breaker has been tripped.
Disconnect non-essential equipment from 
the unit. Reset the circuit breaker. Re-
connect equipment one item at a time. If the 
circuit breaker is tripped again, disconnect 
the device that caused the trip.
The unit does not provide the 
expected amount of backup 
time.
Battery Backup outlets may be fully or 
improperly loaded.
Disconnect non-essential equipment from 
the Battery Backup outlets and connect the 
equipment to 
S
URGE
 O
NLY
 outlets.
The battery was recently discharged due 
to a power outage and has not fully 
recharged.
Charge the battery cartridge for 16 hours.
The battery has reached the end of its 
useful life.
Replace the battery.
Power is not supplied to some 
outlets.
Power to the Controlled outlets has 
intentionally been turned off.
Confirm that the correct peripherals are 
connected to Controlled outlets. If this 
feature is not desired, disable the Power-
Saving Master and Controlled outlets.
The Controlled outlets are not 
supplying power, even though 
the Master device is not in sleep 
mode.
The Master Outlet threshold may be 
incorrectly set.
Adjust the threshold when the Master outlet 
signals the Controlled outlets to shut down.