OKI MC160n Manuel D’Utilisation

Page de 268
229
Troubleshooting
With N-up on 
multiple cop-
ies, the out-
put is 
incorrect.
Both the printer driver 
and the application 
have been set for col-
lation.
For N-up on multiple copies, choose 
Collate only in the printer driver’s Basic 
Tab. Do not set collation in the applica-
tion.
Booklet Left 
and Right 
Binding out-
put is incor-
rect.
Both the printer driver 
and the application 
have been set for col-
lation.
For Booklet Left Binding and Booklet 
Right Binding, choose Collate only in 
the printer driver’s Basic Tab. Do not 
set collation in the application.
You hear 
unusual 
noises.
The machine is not 
level.
Place the machine on a flat, hard, level 
surface.
The tray is not 
installed correctly.
Remove the tray that you are printing 
from and reinsert it completely into the 
machine.
There is a foreign 
object stuck inside 
the machine.
Turn off the machine and remove the 
object. If you cannot remove it, contact 
Technical Support. 
When copy-
ing or scan-
ning with the 
ADF, a band 
appears at 
the end of 
the image or 
paper (5 to 6 
mm).
A malfunction may 
have occurred while 
paper was being 
transferred with the 
ADF.
If a band appears in the copy after 
copying, select a copy density setting 
that is one level darker.
If a band appears in the image after 
scanning, scan using the original 
glass.
Cannot copy 
with the ADF.
Envelope DL or 
Envelope C6 is set to 
the ADF.
Place the document on the original 
glass. With the Envelope DL size, 
some areas may not be copied.
Scanned 
images are 
noisy.
Resolution is set to 
150 x 150 dpi while 
the scan mode is set 
to MIX or TEXT.
Set the scan mode to PHOTO.
Some areas 
of the 
scanned 
image are 
missing.
Acrobat 8 (Macintosh 
version) is used for 
scanning the image.
With the Acrobat Scan setting, turn off 
the OCR and Filtering functions.
Symptom
Cause
Solution