Sony SDZ-S130 Manuel D’Utilisation

Page de 64
23
Chapter 2  Installation
Setting the Loop ID (SDZ-S130 only)
You can set the Loop ID with the loop ID jumpers, if necessary. These jumpers 
are functional when the topology is arbitrated loop. When the jumpers are 
enabled, they acquire AL_PA through LIHA (Loop Initialization Hard 
Assigned). AL_PA is acquired from the loop ID. See table “Arbitrated Loop 
Physical Addresses (AL_PA) and Loop IDs” on page 24 f
or conversion details. 
When the jumpers are disabled, acquisition of AL_PA through LIHA is not 
performed, so AL_PA is acquired from LISA (Loop Initialization Soft 
Assigned).
Caution
• Turn off the unit before setting the Loop ID with the loop ID jumpers. Failing 
to do so may result in damage.
• Do not touch the fibre channel or jumper connectors of the unit when it is on. 
Doing so may result in damage.
LOOP ID
2
1
0
LOOP ID 0
LOOP ID 1
LOOP ID 2
LOOP ID 3
LOOP ID 4
LOOP ID 5
LOOP ID 6
LOOP ID Enab
le
3
4
5
6
0
1
2
3
4
5
6
121
122
123
124
125
Reserved
Reserved
LOOP ID
Fibre channel
connector
Jumpers
LOOP ID Enable
Enable
Disable
Note:
= CLOSED/Jumper
= OPEN/Jumper not installed