Adaptec MAN-FC2002-001 Manuel D’Utilisation

Page de 110
Unpacking and Initial Setup
30
Unpacking and Initial Setup
When you receive your system, visually inspect the exterior 
of the packaging for any signs of damage. If any damage is 
found the carrier and Adaptec should be informed immedi-
ately, and they will advise you of the appropriate action. The 
cartons are sealed using packaging tape which should be cut 
open in the normal manner. Exercise caution when lifting 
out the components. At this point the contents should be 
verified against the packing list and Adaptec should again 
be notified if any discrepancies exist. Anti-static precautions 
must be observed before removing any of the components.
Installing the System in an Equipment Rack
Before installing the 2Gb SANbloc Series in an equipment 
rack, it is essential that the following guidelines are 
complied with, to ensure the safe and efficient operation of 
the system. The 2Gb SANbloc Series can be installed in 
open or closed equipment racks, with a front width of 19”, 
by observing the environmental, electrical, and mechanical 
precautions described below.
Ambient 
Temperature
Installation of the rack system in a standard 19” cabinet may 
lead to a differential between the room ambient temperature 
and the internal ambient temperature of the rack 
environment. The operating temperature of the 2Gb 
SANbloc Series is between 5
o
C to 40
o
C. However, it is not 
recommended that the system be continuously run at these 
extreme temperatures. Consideration should therefore be 
given to ensure that the room ambient temperature is 
compatible with these specifications.