Disk Drive Spin Up Sequence
63
Disk Drive Spin Up Sequence
At power on, the LS module will perform its internal start up 
initialization routine. Then the LS module will assert the 
disk drive START_1 and START_2 motor start signals low 
for disk drive slots 7 through 13, which will spin up the first 
7 disk drives immediately. The LS module will then assert 
the disk drive START_2 motor start signal low and leave the 
START_1 motor start signal high for disk drive slots 0 
through 6 which will command the second seven disk drives 
to spin up after a delay of 12 seconds times the modulo 8 
value of the numeric SEL_ID of the disk drive.
Once the enclosure is powered up and all 14 drives are spun 
up as depicted above, the enclosure will support immediate 
drive spin up with two power supplies present.
Modulo 8
The drive spin up sequence above uses modulo 8 to calculate 
the spin up delay. Modulo 8 is determined by:
(SHELF ID x DRIVE NUMBER)/8 = NUMBER + REMAINDER
It is the REMAINDER value that is used for the calculation 
as it is always between 0 and 7 (hence modulo 8). The drive 
spin up time can then be calculated as follows:
REMAINDER x MODE PAGE SETTING = SPIN UP DELAY (Seconds)
EXAMPLE: 
A typical Mode Page Setting is 12, so if the 
Remainder = 7, the Spin Up Delay would be 7 x 12, or 84 
seconds.