Chapter 5: System Monitoring
This Chapter describes the devices used to monitor the 
2Gb SANbloc Series. The location of the monitoring LEDs 
and how to interpret them is described.
Overview
The front mounted LS module is the main monitoring 
device of the 2Gb SANbloc Series. This module is comple-
mented by status and fault LEDs, mounted on all the major 
components of the enclosure, such as, disk drives, power 
supplies, Advanced Cooling Modules (ACMs), and RAID 
Controller. All these monitoring devices are discussed in the 
following sections.
LS Module
The LS Module (Loop Resiliency and SES Module) 
provides monitoring and control for the 2Gb SANbloc 
Series. The module reports status and receives control infor-
mation over the Enclosure Services Interface (ESI) port of 
any of the fourteen disk drives installed in the enclosure. 
The LS Module also provides loop resiliency for the Fibre 
Channel loop (in the form of Port Bypass Circuits).
The 2Gb SANbloc Series contains one LS Module as 
standard. However, a second optional LS Module is 
available to provide active/passive fail-over for the 
enclosure services communication, and to provide a second 
Fibre Channel Loop. Only one LS Module communicates 
(using ESI communication) with the host system at any one 
time, but both LS modules will continuously monitor the