Cisco Systems 15454M6DC Manuel D’Utilisation

Page de 458
 
8-24
Cisco ONS 15454 Installation and Operations Guide
November 2001
Chapter 8      Performance Monitoring
Performance Monitoring for Electrical Cards
8.5.4  DS3-12E and DS3N-12E Card Performance Monitoring Parameters
 shows the signal types that support far-end PMs. 
 shows where overhead bytes 
detected on the ASICs produce performance monitoring parameters for the DS3-12E and DS3N-12E 
cards.
DS3 AISS-P
Alarm Indication Signal Seconds-Path (AISS-P) is a count of seconds 
containing one or more AIS defects.
DS3 UAS-P
Unavailable Seconds-Path (UAS-P) is a count of one-second intervals 
during which the DS3 path is unavailable.
Table 8-15 Near-End SONET Path PMs for the DS3 and DS3N Cards
Parameter
Definition
STS CV-P
Near-End STS Path Coding Violations (CV-P) is a count of BIP errors 
detected at the STS path layer (i.e., using the B3 byte). Up to eight BIP 
errors can be detected per frame; each error increments the current CV-P 
second register.
STS ES-P
Near-End STS Path Errored Seconds (ES-P) is a count of the seconds 
when at least one STS path BIP error was detected. An AIS-P defect (or a 
lower-layer, traffic-related, near-end defect) or an LOP-P defect can also 
cause an STS ES-P. 
STS FC-P
Near-End STS Path Failure Counts (FC-P) is a count of the number of 
near-end STS path failure events. A failure event begins when an AIS-P 
failure, an LOP-P failure, a UNEQ-P, or a TIM-P failure is declared. A 
failure event also begins if the STS PTE that is monitoring the path 
supports ERDI-P for that path. The failure event ends when these failures 
are cleared.
STS SES-P
Near-End STS Path Severely Errored Seconds (SES-P) is a count of the 
seconds when K (2400) or more STS path BIP errors were detected. An 
AIS-P defect (or a lower-layer, traffic-related, near-end defect) or an 
LOP-P defect can also cause an STS SES-P.
STS UAS-P
Near-End STS Path Unavailable Seconds (UAS-P) is a count of the 
seconds when the STS path was unavailable. An STS path becomes 
unavailable when ten consecutive seconds occur that qualify as SES-Ps, 
and it continues to be unavailable until ten consecutive seconds occur that 
do not qualify as SES-Ps.
Table 8-14 Near-End DS3 Path PMs for the DS3 and DS3N Cards (continued)
Parameter
Definition