Hardware Maintenance Manual: xSeries 250
 
 
New controller installed in a configured server or drives are imported.
Explanation:  
When the ServeRAID controller detects that the identifiers of the drives do not  
match the controller configuration information, the following message appears:  x online 
drive(s) found with mismatch configuration   Examples of possible messages:  
Configuration mismatch Channel 1 SCSI ID 0 with Host ID
Configuration mismatch Channel 2 SCSI ID 0 with Host ID
Action:  
Press one of the following keys: 
F2 – 
Detailed description.   Press this key for a detailed description of the problem, such as the 
example messages above.
F4 – 
Retry.   Press this key after correcting the problem.  For example, press F4 after you move 
the physical drive to its previously assigned location, or after you install the original physical 
drives back in the server.
F5 – 
Change the configuration and set the drive to defunct.  Press this key to accept the new 
state that the ServeRAID controller will assign to the drive.  For example, the ServeRAID 
controller will assign the drive a state of defunct or empty.
Note:
  A physical drive in the defunct state does not necessarily mean that you need to 
replace the drive.  Before you replace the drive, ensure that: 
1.
All cables are connected properly to the backplane or processor or I/O board, and to the 
physical drive.  Also, ensure that all cables inside the server are connected properly.
2.
The hot-swap drive trays are seated properly in the drive bay.
3.
If you have not already attempted to rebuild the drive, try rebuilding it.  See “Rebuilding 
a defunct drive” on page 23
 for more information.
After you perform these steps, if the physical drive does not function properly, replace the 
drive.
F7 – 
Import configuration information from drive.  Press this key to restart the server.  Press 
this key to import the configuration information from the drive and to update the 
configuration information for the ServeRAID controller.  This choice is useful when you 
replace the ServeRAID controller in an existing ServeRAID subsystem.   You also might press 
F7 if you replace a whole set of drives with drives that were configured in another server with 
a ServeRAID controller.  When you install drives in a server that has no logical drives 
defined, the F7 choice will not appear.  The ServeRAID controller does not contain any logical 
drives in its factory configuration.  Therefore, F7 will not  appear.  In this case, do the 
following:
1.
Restart the server and press Ctrl+I to enter the Mini-Configuration program (see “Using 
the ServeRAID Mini-Configuration program” on page 130
).
2.
Select Advanced Functions.
3.
Select Copy the Configuration from Drives to the Controller and follow the instructions 
on the screen.
Recoverable configuration error.
Explanation:  
The configuration data stored in NVRAM does not match the configuration 
data stored in the EEPROM.
Action:  
1.
Press Ctrl+I to access the ServeRAID Mini-Configuration menu.  
2.
Select Advanced Functions from the Main Menu.
3.
Select Copy the Configuration from Drives to the Controller.