Lenovo 6532 Manuel D’Utilisation

Page de 240
Information
Information messages do not require action; they
record significant system-level events, such as
when the server is started.
Warning
Warning messages do not require immediate action;
they indicate possible problems, such as when the
recommended maximum ambient temperature is
exceeded.
Error
Error messages might require action; they indicate
system errors, such as when a fan is not detected.
Each message contains date and time information, and it indicates the source of the message (POST
or the IMM).
Integrated management module error messages
The following table describes the IMM error messages and suggested actions to correct the detected
problems.
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Message
Severity
Description
Action
Numeric sensor Ambient Temp going
high (upper critical) has asserted.
Error
An upper critical sensor
going high has asserted.
Reduce the ambient temperature.
Numeric sensor Ambient Temp going
high (upper non-recoverable) has
asserted.
Error
An upper nonrecoverable
sensor going high has
asserted.
Reduce the ambient temperature.
Numeric sensor Planar 3.3V going
low (lower critical) has asserted.
Error
A lower critical sensor going
low has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar 3.3V going
high (upper critical) has asserted.
Error
An upper critical sensor
going high has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar 5V going low
(lower critical) has asserted.
Error
A lower critical sensor going
low has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar 5V going high
(upper critical) has asserted.
Error
An upper critical sensor
going high has asserted.
(Trained service technician only)
Replace the system board.
Numeric sensor Planar VBAT going
low (lower critical) has asserted.
Error
A lower critical sensor going
low has asserted.
Replace the 3 V battery.
Numeric sensor Fan n Tach going low
(lower critical) has asserted.(n = fan
number)
Error
A lower critical sensor going
low has asserted.
1. Reseat the failing fan n,
which is indicated by a lit
LED on the system board (see
“System-board LEDs” on page
112
).
2. Replace the failing fan.
(n = fan number)
Chapter 4
.
Diagnostics
27