Lenovo 6532 Manuel D’Utilisation

Page de 240
• Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
• If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
The Processor CPU nStatus has
Failed with IERR.(n = microprocessor
number)
Error
A processor failed - IERR
condition has occurred.
1. Make sure that the latest levels
of firmware and device drivers
are installed for all adapters
and standard devices, such as
Ethernet, SCSI, and SAS.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code
is supported for the cluster
solution before you update the
code.
2. Run the DSA program for the
hard disk drives and other I/O
devices.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
An Over-Temperature Condition has
been detected on the Processor CPU
nStatus.(n = microprocessor number)
Error
An overtemperature
condition has occurred
for microprocessor n.(n =
microprocessor number)
1. Make sure that the fans are
operating, that there are no
obstructions to the airflow, that
the air baffle is in place and
correctly installed, and that
the server cover is installed
and completely closed.
2. Make sure that the heat
sink for microprocessor n is
installed correctly.
3. (Trained service technician
only) Replace microprocessor
n.
(n = microprocessor number)
28