Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB Web-UI (Web User Interface) Operations 
 
1.7 
[System] Menu for PRIMEQUEST 2800B 
In [System] menu, it is possible to display and set the status of all the hardware components in the 
PRIMEQUEST PRIMEQUEST 2800B system. 
A display and a set item of [System] menu are different in PRIMEQUEST 2400E and PRIMEQUEST 2800E.  
Refer to Chapter 1.3 for details. 
 
Remarks 
If “Read Error” is displayed for [Part Number] and [Serial Number] on MMB Web-UI (contents area and 
information area), confirm the problem by referring to “11.2 Troubleshooting” of 
PRIMEQUEST 2000 Series 
Administration Manual
 (C122-E175EN). If the error could not be resolved, contact your sales representative 
or repairs assistance service. 
Confirm the model name and serial number shown on the label affixed on the main unit and report it. 
 
1.7.1  [System Status] window 
[System Status] window shows the status of entire PRIMEQUEST 2800 model. The contents displayed may 
differ depending on the configuration of the unit. 
You can also display details of each unit by clicking the link displayed in the frame. 
.
 
FIGURE 1.96 [System Status] window 
 
 
The contents which are displayed as the status of unit are as follows. 
[OK]   
: It is shown for the unit which operates normally without any trouble. 
[Not-present] 
: It is shown for the unit which is not mounted. It is shown in gray colored background. 
[Warning]           : Though it is not serious, it shows the unit where a problem may occur. It is shown by  
 
icon. 
[Failed]               : It shows the unit, where failure has occurred, and it must be disconnected. It is shown by  
 icon. 
[Degraded]         : It shows that a failure has occurred in the component of a certain unit, and the unit is 
operated without disconnecting the failed component. It is shown by 
 icon.