Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB Web-UI (Web User Interface) Operations 
 
FIGURE 1.97 [System Event Log] window 
 
 
In the [System Event Log] Window, only the contents and not the title in the table can be scrolled. When 
there are no events to be displayed, a message showing “There is no Event Logs.” is displayed instead of 
the table. 
 
TABLE 1.132 Items displayed in [System Event Log] Window 
Items 
Description 
Severity 
Displays the severity of the event and error 
· 
Error  : Severe errors like hardware error 
· 
Warning  : Not a severe error, but an error is likely in future 
· 
Info  : Shows the information like ‘Partition power ON’ 
Date/Time 
Displays the local time when an event or error occurred. 
Format: YYYY-MM-DD HH:MM:SS 
Source 
Displays the name of the sensor where an event or error occurred. 
Unit 
Displays the unit with the sensor where an event or error occurred. 
For example, displays [SB#0] if an error occurs in CPU#0 of SB#0. 
This unit retrieves FRU with this sensor from Entity ID of the sensor, and also retrieves 
Parent Entity from Entity Association Record. It displays Board/Unit name described in 
FRU Record of parent entry.  
It is linked to the window (Window on which part number and serial number of each unit 
can be referenced) showing detailed status of each unit. 
Part Number 
Displays the part number stored in system event log. If part number is not stored, “ 
-” is 
displayed. 
Event ID 
Displays the ID (8 digits in hexadecimal system) for identifying contents of Event.  
For details on the allocation of the Event ID, see “Chapter 2 MMB Message” of 
PRIMEQUEST 2000 Series Message Reference
 (C122-E178EN). 
Description 
Displays the contents of Events and Errors. 
Remarks 
For the event of insertion/removal of the board, part number and serial number of board 
are displayed.