MMB Web-UI (Web User Interface) Operations 
 
FIGURE 1.11 [System Setup] Window 
 
 
TABLE 1.32 Display Items and Setting Items in [System Setup] Window 
Items 
Description 
Input Voltage 
Displays input voltage. 
· 
100V 
· 
200V 
 
When information cannot be acquired, it is displayed as 200V. 
Power Feed Mode 
Whether power supply of PRIMEQUEST 2000 system is configured in primary 
power feed mode or dual power feed mode is set. 
· 
Single: primary power feed mode 
· 
Dual: dual power feed mode 
 
Default setting is Single. 
Power Restoration 
Policy 
Sets the display of the restoration action after power failure. 
· 
Always off: Maintains the power-off status after the power restoration. 
· 
Always on: Regardless of the condition at the time of power failure, the 
partition is powered on after the power restoration. 
· 
Restore: Restores the status immediately before the power failure. If the 
power was on when the power failure occurred, it restores the power-on 
status of the partition. If the power was off, the partition power stays off. 
· 
Schedule Sync: If the partition is in the operating time zone, power of partition 
turns on automatically depending on the schedule operations at the time of 
restoration of power. 
(attention) 
The schedule set with Special is applied only on the specified day. 
Default setting is Restore. 
Partition Power On 
Delay 
Sets the standby time utill power on of partition is specified as per the restoration 
power policy that is set after the AC power is On (also includes restoration power).