Fujitsu C122-E177-01EN Manuel D’Utilisation

Page de 512
MMB Web-UI (Web User Interface) Operations 
 
[System] – [System Setup] 
 
(2)  Window Operations 
Specify the items such as [Power Feed Mode] and [Power Restoration Policy] and click on the [Apply] 
button. 
Respective information is set. 
 
[Message] 
 
This section describes the messages to be displayed on this window. 
Message Number 
Message 
I_00013 
Setting completed. 
E_00100 
Failed to set the System Setup 
W_00426 
Invalid values specified. 
 
For details on the messages displayed on the window, see 
PRIMEQUEST 2000 Series Message Reference
 
(C122-E178EN). 
 
 
1.2.8  [System Power Control] window 
In [System Power Control] window, power of the entire PRIMEQUEST 2000 series system can be controlled. 
 
Remarks 
 
· 
Please shutdown the OS for the partition in which Windows is installed. In case of emergency such as, 
no response from the system, cut the power supply using Power Off (Force Power Off) of MMB. 
· 
In case of following condition, confirm the contents by referring to "11.2 Troubleshooting" of 
PRIMEQUEST 2000 Series Administration Manual
 (C122-E175EN). If the error could not be solved, 
contact your sales representative or sales representative. 
Confirm the model name and serial number shown on the label affixed on the main unit and report it. 
Moreover, do not [Reset] or [Force Power Off] the partition till the error is solved. 
When [Power off], [Reset], [Force Power Off] and shut down of partition is done by  operating 
system, and if the state of each component on the MMB Web-UI screen is displayed in the state in 
which processing does not end even for a long time, Part Number and Serial Number are 
displayed as "Read Error".