System Management:
 FRU LEDs
7-21
Set FRU LED State Command 
The Set FRU LED State command allows the state of the FRU LEDs to be controlled by the 
management system.
Table 7-14:
Set FRU LED State Command
Type:
Byte:
Data Field:
Request Data
1
PICMG Identifier—indicates that this is a PICMG defined group 
extension command. Use value 00h.
2
FRU Device ID
3
LED  ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh Lamp Test (all LEDs under management control are 
addressed)
4
LED Function
00h LED off override
01h-FAh LED blinking override
FBh Lamp Test state Turn on LED specified in byte 3 for the 
duration specified in byte 5, then return to the highest 
priority state.
FCh LED state restored to Local Control state
FDh-FEh reserved
FFh LED on override
5
On  Duration
LED on-time is measured in tens of milliseconds 
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time 
value must be less than 128. Other values when Byte 4=FBh are 
reserved. Otherwise, this field is ignored and shall be set to 0h.