Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
System Management:
 FRU LEDs
7-23
Response Data
3
LED States
Bits [7:3] reserved, set to 0
Bit [2] 1b if Lamp Test has been enabled
Bit [1] 1b if override state has been enabled
Bit [2] 1b if IPMC has a Local control state
4
Local Control LED Function
00h LED is off (default if Local Control not supported)
01h-FAh LED is blinking Off duration specified by this byte, 
on duration specified by byte 5 (in tens of 
milliseconds)
FBh-FEh reserved
FFh LED is on
5
On  Duration
LED on-time is measured in tens of milliseconds 
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time 
value must be less than 128. Other values when Byte 4=FBh are 
reserved. Otherwise, this field is ignored and shall be set to 0h.
6
Local Control Color
Bits [7:4] reserved, set to 0
Bits [3:0] 
0h reserved
1h Blue
2h Red
3h Green
4h Amber
5h Orange
6h White
7h-Fh reserved
7
Override State LED Functionis required if either override state or 
Lamp Test is in effect.
00h LED override state is off 
01h-FAh LED override state is blinking Off duration is 
specified by this byte, on duration specified by 
byte 8 (in tens of milliseconds)
FBh-FEh reserved
FFh LED override state is on
8
Override State On Durationis required if either override state or 
Lamp Test is in effect (in tens of milliseconds). 
Type:
Byte:
Data Field:
  (continued)