Emerson ATCA-9305 Manuel D’Utilisation

Page de 184
Management Processor CPLD:
 MPC8548 PLD Register 
5-3
PLD Version
This read-only register tracks PLD revisions.
Register 5-3:
PLD Version (0x08)
PLL Reset Configuration
Write to this register to reconfigure the SYSCLK to CCB clock ratio and the CCB to CORE 
clock ratio using valid values from the MPC8548E PowerQUICC™ III Integrated Processor Family 
Reference Manual
. The changes take affect when the processor is reset (for example, the 
software hard reset command or watchdog timer expires). Default values are restored 
when the board is power-cycled, front panel reset is pressed, or receives a PCI reset that was 
not the result of the MPC8548 software initiating a PCI RSTOUT command.
Register 5-4:
PLL Reset Configuration (0x0C)
Hardware Configuration 0
The read-only HCR0 allows the MPC8548 monitor software to easily determine specific 
hardware configurations, such as the processor clock and MPC8548 DDR memory.
Bits:
Function:
Description: 
7
0
This is hard coded in the PLD and changes with every released code 
change. Version starts at 00
16
.
6
0
5
0
4
0
3
0
2
0
1
0
0
0
Bits:
Function:
Description: 
7
reserved
6
CCCB2
CCB2 to CORE clock ratio
5
CCCB1
CCB1 to CORE clock ratio
4
CCCB0
CCB0 to CORE clock ratio
3
CCBSYS3
SYSCLOCK3 to CCB clock ratio
2
CCBSYS2
SYSCLOCK2 to CCB clock ratio
1
CCBSYS1
SYSCLOCK1 to CCB clock ratio
0
CCBSYS0
SYSCLOCK0 to CCB clock ratio