Emerson MVME147 Manuel D’Utilisation
![Emerson](https://files.manualsbrain.com/attachments/1ef3aaad462e024fde6cecf537a4c6c781334d44/common/fit/150/50/6dab323528eefa0342baa74a10c15551c3b956250cf9d62f2117dcdf42a7/brand_logo.jpeg)
SCSI PACKETS
7-56
7
+$00
Controller LUN
Device LUN
+$02
Status Byte 0
Status Byte 1 (Note 1)
+$04
0
0
Inquiry Data Length
+$06
Inquiry Data Pointer (MSW)
+$08
Inquiry Data Pointer (LSW)
+$0A
0
0
0
0
+$0C
0
0
0
0
+$0E
0
0
0
0
+$10
0
0
0
0
+$12
0
0
0
0
+$14
0
0
Function Code (50)
+$16
Interrupt Level
Vector Number
+$18
Status Byte 2
Status Byte 3 (Note 1)
$00
00000xxx
Controller logical unit
number
number
$01
00000xxx
Device logical unit
number
number
$02
xxxxxxxx
Status from SCSI
firmware (byte 0)
(Note 1)
firmware (byte 0)
(Note 1)
$03
xxxxxxxx
Status from SCSI
firmware (byte 1)
(Note 1)
firmware (byte 1)
(Note 1)
$04
00000000
Reserved
$05
xxxxxxxx
Maximum inquiry
data length ($00 -
$FF)
data length ($00 -
$FF)
$06
xxxxxxxx
xxxxxxxx
Inquiry data pointer
(MSW)
(MSW)
$08
xxxxxxxx
xxxxxxxx
Inquiry data pointer
(LSW)
(LSW)
$0A
00000000
00000000
Reserved
$0C
00000000
00000000
Reserved
$0E
00000000
00000000
Reserved
$10
00000000
00000000
Reserved
$12
00000000
00000000
Reserved