cgmControl
MIB Description
PMC-CGM Installation and Use (6806800D53C)
53
 
The following table describes the elements of the cgmControl MIB branch 
(OID:.1.3.6.1.4.1
.3656
.8152.1.1).
.1.1.2.1.116
bitsTestPatternType
Determines the type of the generated test pattern.
fixed(0) to use a pattern as defined in 
bitsTestPattern / bitsTestPatternLength.
prbs11 (1)
prbs15 (2)
qrss20 (3)
Default value is (1).
Applies to the following line-type settings:
dsx1ESF
dsx1D4
dsx1E1
dsx1E1CRCMF
dsx1E1unframed
r/w
Table 5-5 cgmControl Elements
OID
MIB Object
Description
Access
.1.1.10
cgmInterfaceMode
Defines Sonet/T1 (0) or SDH/E1 (1) operation 
mode for both BITS interfaces. Affects whether 
an input frequency of 1544KHz (Sonet/T1) or 
2048KHz (SDH/E1) can be selected for the 
cgmInputFrequency object.
Default value is (1).
r/w
.1.1.15
cgmMasterSlaveShelfCombin
ation
Defines whether the master/slave combination is 
on the same shelf (0) or on different shelves (1).
Note: only "same shelf" is supported.
Default value is (0).
r/w
.1.1.16
cgmMasterSlaveSync
Defines the communication path to the protection 
partner.
Default value is backplane (0).
r/w
.1.1.18
cgmProtectionRevertiveMode
State
When a clock module is in revertive operation 
(0), it will always choose the highest priority valid 
input. 
When in nonrevertive operation (1), a selected 
input will remain selected until it fails. The highest 
priority valid input will be chosen at that point and 
remain selected until it fails as well.
Default value is (1).
r/w
Table 5-4 cgmBitsTable (continued)
OID
MIB Object
Description
Access