The following table lists all event codes and their severity. Events which cause the module to 
give up mastership are marked with an asterisk in the "severity" column.
.1.3.1.1.4
cgmEventCode
A pre-defined event code - for details refer to 
.
r
.1.3.1.1.5
cgmEventData
Event specific data
r
.1.3.1.1.6
cgmEventDescr
Textual event description
r
Table 5-7 Event Codes and Severity
Code
Severity
Description
inputChanged (1)
Event
The selected PLL input has changed.
lostLock (2)
Event
The T0 PLL lost lock and enters holdover mode.
gainedLock (3)
Event
The PLL gained lock.
nowMaster (4)
Event
The module has acquired mastership.
nowSlave (5)
Event
The module has entered slave mode.
validInputsChanged (6)
Event
The validity or more of the PLL inputs has changed .
selectedInputFailed (7)
Event
The selected clock input has failed.
dpllInitError (10)
Warning
Error while initializing the DPLL.
freqValidationError( 11)
Warning
One of the clock sources measured in the FPGA is out 
of range.
inputStateChange (12)
Event
Reported when a state change is detected by the 
activity monitor.
EventData: Upper 16 bits encode the new state, lower 
16 bits encode the input number.
State can be 
0 (working)
1 (failing)
2 (failed)
3 (recovering)
4 (unknown)
This is the same information as presented in the 
cgmInputActivityMonitor element.
lineCardClkError (20)
Warning
Not applicable for PMC-CGM.
lineCardClkSelected (21)
Event
Not applicable for PMC-CGM.
bitsRlof/c (30/34)
Event
"Loss of frame" / "Loss of frame cleared" event  
detected on a BITS interface.
EventData: The BITS interface on which the event has 
been detected (0 or 1).
Table 5-6 cgmEventTable (continued)
OID
MIB Object
Description
Access