Emerson 752I Manuel D’Utilisation

Page de 172
IPMI Controller:
 IPMI Message Protocol
11-17
Set Heartbeat (OEM)
The Set Heartbeat command configures the Zircon PM to send a heartbeat message to a 
receiver on the IPMB or private I
2
C bus at a specific interval. The interval can range between 
100 milliseconds and 25.6 seconds. The heartbeat message data may be a string of bytes or 
a command that gets processed at each interval. 
 shows the request/response 
data parameters for the Set Heartbeat command.
Table 11-13:
Set Heartbeat Parameters
Type:
Byte:
Data Field:
Request 
Data
1
Bus  ID
Bits[7:4, Reserved
Bits[3:1], Bus ID, zero-based
000=Public IPMB
001=Private IIC Bus #1, Private IPMB
111=Private IIC Bus #2
Bit[0], Bus Type
0=Public (IPMB)
1=Private Bus
2
Bits[7:1], Slave Address of Recipient
Bit[0], Reserved. Write as zero.
3
Send  Interval 
The interval in 100-millisecond counts between heartbeat 
transmissions. Writing zero disables the heartbeat.
4
Command/Data
0=Following is a command to be processed. Its reply data is to be 
sent for the heartbeat data.
1=Following is constant data to be sent for the heartbeat data.
5:N
Command or Constant Data
If the data is a command to be processed, this field must contain a 
properly formatted IPMB message, minus the first byte 
containing the slave address.
Response 
Data
1
Completion  Code