IPMI Controller:
 IPMI Message Protocol
11-18
Get Heartbeat (OEM)
The Get Heartbeat command returns the current configuration of the heartbeat function 
for a specified interface. The response data has the same definition as the Set Heartbeat 
request data (see Section )
 shows the request/response data parameters for the 
Get Heartbeat command.
Table 11-14:
Get Heartbeat Parameters
Type:
Byte:
Data Field:
Request 
Data
1
Bus  ID
Bits[7:4], Reserved
Bits[3:1], Bus ID, zero-based
000=Public IPMB
001=Private IIC Bus #1, Private IPMB
111=Private IIC Bus #2
Bit[0], Bus Type
0=Public (IPMB)
1=Private Bus
Response 
Data
1
Completion  Code
2
Bits[7:1], Slave Address of recipient
Bit[0], Reserved. Returned as zero. Ignore on read.
3
Send  Interval. 
The interval in 100-millisecond counts between heartbeat 
transmissions. Zero indicates that the heartbeat is disabled.
4
Command/Data
0=Following is a command to be processed. Its reply data is to be 
sent for the heartbeat data.
1=Following is constant data to be sent for the heartbeat data.
5:N
Command or Constant Data