IPMI Controller:
 IPMI Message Protocol
11-20
IPMI Device SDR Repository
The Zircon PM implements a Device SDR Repository that contains Sensor Data Records for 
the Zircon PM, the FRU device, and each sensor. A system management controller may use 
the Get Device SDR command to read the repository and dynamically discover the capabili-
ties of the board. Please refer to the IPMI specification (listed in 
) for more informa-
tion on using Sensor Data Records and the Device SDR Repository.
IPMI Event Messages
Under certain circumstances, some sensors connected to the Zircon PM can generate Event 
Messages for the system management controller, as described below in 
Table 11-16:
IPMI Event Messages Generating Sensors
To enable these messages, the system management controller must send a Set Event 
Receiver command to the Zircon PM, along with the address of the Event Receiver. 
 shows the format of an Event Message.
Table 11-17:
Event Message Format
Sensor Name:
Sensor 
Type:
Event/Reading 
Type:
Sensor 
Number:
Event 
Generator:
ProcProgress
0x0F
0x6F
0x70
Yes
ProcWatchdog
0x23
0x6F
0x50
Yes
OutflowTemp
0x01
0x01
0x60
Yes
InflowTemp
0x01
0x01
0x61
Yes
+5.0V
0x02
0x01
0x46
Yes
+3.3V
0x02
0x01
0x45
Yes
+2.5V
0x02
0x01
0x44
No
+1.8V
0x02
0x01
0x43
No
PPC750GL
0x02
0x01
0x42
No
PMC+3.3V
0x02
0x01
0x41
No
Byte:
1
Field:
Description:
0
RsSA
Responder’s Slave Address (Address of Event Receiver)
1
NetFn/RsLUN
Net Function Code (0x04) in upper 6 bits; Responder’s LUN in lower 
2 bits
2
Chk1
Checksum #1
3
RqSA
Requester’s Slave Address (Address of our board on IPMB)
4
RqSeq/RqLUN
Request Sequence number in upper 6 bits; Requester’s LUN in low 
2 bits
5
Cmd
Command (Always 0x02 for event message)
6
EvMRev
Event Message Revision (0x04 for IPMI 1.5)