Omron C200HE Manuel D’Utilisation

Page de 564
401
7-2-8
Differentiation Monitor
This operation can be used to monitor the up or down differentiation status of bits
in the IR, SR, AR, LR, HR, and TC areas. To monitor up or down differentiation
status, display the desired bit leftmost on the bit monitor display, and then press
SHIFT and the Up or Down Arrow Key.
A CLR entry changes the Differentiation Monitor operation back to a normal bit
monitor display.
Key Sequence
Bit monitor in progress
L000000108H2315 
  OFF  OFF   ON
L000000108H2315 
U@OFF  OFF   ON
L000000108H2315 
  OFF  OFF   ON
D0002
 0123
Monitor the desired bit so that it is
leftmost on the screen.
Press SHIFT and Up Arrow to
specify up differentiation (U@).
(Press SHIFT and Down Arrow to
specify down differentiation (D@).
The buzzer will sound when up
(U@) or down (D@) differentiation is
detected.
The original bit monitor display will
return when differentiation
monitoring is completed.
Press CLR to cancel differentiation
monitoring and return to the original
bit monitor display.
Example
Programming Console Operations
Section 7-2