Mocomtech CDM-570L Manuel D’Utilisation

Page de 452
CDM-570/570L Satellite Modem with Optional IP Module 
Revision 4 
Appendix D 
MN/CDM570L.IOM 
D.4.1 easyConnect
 Mode Troubleshooting 
Use the following troubleshooting steps if unable to successfully send traffic in 
easyConnect
™. 
easyConnect
 Mode Troubleshooting 
Step
Problem
Action
a)
 
Verify correct IP address/subnet on PC and 
CDM-IP. 
No Ping response from the 
locally connected PC to the 
CDM-IP Ethernet port. ICMP 
response is ‘Request timed out’. 
b)
 
Verify Ethernet connection – cables, hub, etc. PC, 
hub, and CDM-IP should have Ethernet activity 
LED lit. 
Note:  A PC must be connected to the CDM-IP 
using a hub, switch or a RJ45 crossover 
cable. When the CDM-IP Ethernet port 
senses an Ethernet connection, the CLI 
will display: 
phymon_callback():  enet link change!  link=1 
If the connection is broken, the CLI will 
display: 
phymon_callback():  enet link change!  link=0 
D–12