Mocomtech CDM-570L Manuel D’Utilisation

Page de 452
CDM-570/570L Satellite Modem with Optional IP Module 
Revision 4 
Appendix D 
MN/CDM570L.IOM 
easyConnect
 Mode Troubleshooting 
No Ping response from the 
locally connected PC to the 
remote CDM-IP or remote PC. 
ICMP response is ‘Request 
timed out’. 
 
a) 
Verify both CDM-IP’s are in easyConnect
™/Point-
to-Point Modes.  
b) 
Verify IF link between modems for proper settings 
and carrier quality (RX signal level, E
b
/N
0
, etc.). It 
is possible that there is a spectrum inversion, 
particularly if you are using the CDM-IP with RF 
converter equipment. If this is the case, the signal 
level & E
b
/N
0
 may be OK, but no data will be 
received. To correct this, invert the TX and RX 
Spectrum on one of the CDM-IPs. 
c) 
Send a constant ping from the PC 1 ‘ping 
172.16.10.2 –t’ to PC 2. In the CDM-IP1, go to 
Operations and Maintenance/Diagnostics. Enable 
‘Dump Packets transmitted to Satellite Interface’. 
Verify that the Pings are being transmitted by 
observing 1 packet on CLI every second. If not 
displayed, reverify PC 1 and CDM-IP 1 settings. 
Disable ‘Dump Packets transmitted to Satellite 
Interface’ by entering ‘T’. 
d) 
Continue sending constant ping from the PC 1 to 
PC 2. In the CDM-IP 2, go to Operations 
Maintenance/Diagnostics. Enable ‘Dump Packets 
received from Satellite Interface’. Verify that the 
Pings are being received by observing 1 packet on 
CLI every second. If not displayed, reverify PC 2 
and CDM-IP 2 settings. Disable ‘Dump Packets 
received from Satellite Interface’ by entering ‘R’. 
Note:  All pings transmitted will require a reply to 
be transmitted from the target host. Use 
the Diagnostics ‘Dump Packets’ tools to 
isolate where packets are lost in the CDM-
IP duplex paths. Also, always disable 
‘Dump Packets’ before sending live traffic. 
 