Cisco Systems Gateway 10 Manuel D’Utilisation

Page de 40
17
 
Figure 12
Chassis Installation Bracket
Step 4
With two people, lift the chassis (partially unloaded) into position between the rack posts and rest it on the chassis 
installation bracket.
Step 5
Position the chassis until the rack-mounting flanges flush against the mounting rails on the rack.
Step 6
Hold the chassis in position against the mounting rails and follow these steps:
a.
Insert a bottom screw into the rack-mount ear on each side and use a hand-held screwdriver to tighten the screw to the 
rack rail.
Tip
In the next step, insert the top screw diagonally from the bottom screw that you just attached. This helps to keep the 
chassis in place.
b.
Insert a top screw into each side rack-mount bracket and tighten the screw to the rack rail.
c.
Insert a minimum of four screws per bracket on both sides of the chassis.
Step 7
Ensure that all the screws on each side of the rack-mount brackets are tightened to the equipment rack before the chassis 
installation bracket is removed from the rack.
Connecting the Chassis to Ground
Connecting the Cisco RFGW-10 chassis to the earth ground is required for all installations. The earth ground connections 
located on the faceplate of each DC PEM must be connected to the earth ground. For installations requiring NEBS certification, 
a dedicated double hole lug chassis ground connection point is provided in the lower left corner on the rear of the chassis.
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of 
a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if 
you are uncertain that suitable grounding is available. 
Statement 1024