Callback Security Calling Procedures 
Standard - Predefined Location Only 
Use the following steps when calling from a fixed location predefined in the Callback Security tables. 
1.  Using a communications program such as Hyper Terminal, dial the number of the integrated 
modem in the Sentry unit. 
2.  At the Password> prompt, enter the password for the number being connected from and press 
Enter
 
When a valid password is provided, OK Disconnecting is displayed and the Sentry integrated 
modem disconnects. 
3.  After the specified Callback delay has elapsed, the Sentry integrated modem attempts to connect with 
the Callback dial string associated with the supplied password. 
NOTE:  If unable to establish a connection, the modem will retry until the maximum Callback Attempts has been reached.
 
4.  After the modem reconnects, at the Password> prompt, re-enter the predefined password for the 
number being connected from and press Enter
 
When a valid password is provided, OK Connecting is displayed and access to the Sentry is 
granted. 
 
You are given three attempts to enter a valid password.  If all three attempts fail, the modem will 
automatically disconnect. 
Dynamic Callback number entry 
Mobile users may need to use this procedure when connecting from a number different than the one 
stored with the password.  The + option must have been used in the original configuration of the 
Callback dial string.  See Setting Callback dial strings on page 7 for more information. 
1.  Use the standard procedure with the following deviation. 
2.  At the Password> prompt, enter the password for a number entry enabled number, followed by +
and the new dial string (ex: atdt7752842065). Press Enter
 
When a valid password is provided, OK Disconnecting is displayed and the Sentry integrated 
modem disconnects.    
 
The procedure continues as noted in #3 and 4 above. 
Dynamic Callback extension entry 
Users may need to use this procedure when an extension number must be provided for the dial string 
being called.  The + and ,??? options must have been used in the original configuration of the Callback 
dial string.  See Setting Callback passwords on page 7 for more information. 
1.  Use the standard procedure with the following deviation. 
2.  At the Password> prompt, enter the password for an extension entry enabled number, followed by 
+, and the required extension number.  Press Enter
 
When a valid password is provided, OK Disconnecting is displayed and the Sentry integrated 
modem disconnects.    
 
The procedure continues as noted in #3 and 4 above. 
Direct connection without Callback 
Use this procedure to make a direct connection to the Global Security Modem without a callback. The - 
option must have been used in the original configuration of the Callback dial string.  See Setting 
Callback dial strings
 on page 7 for m
ore information. 
1.  Use the standard procedure with the following deviation. 
2.  At the Password> prompt, enter the predefined password for the number being connected from, 
followed by -, and press Enter
 
When a valid password is provided, OK Connecting is displayed and access to the Sentry is 
granted. 
 
You are given three attempts to enter a valid password.  If all three attempts fail, the modem will 
automatically disconnect. 