Server Technology Global Security Modem Manuel D’Utilisation

Page de 22
 
Configuring the Country Code 
The Sentry integrated Modem is compliant for use per Telecom Certification for the countries listed in 
the following table.  The AT%T19,0, command is used to set the country code.  The default value is 34. 
NOTE: For countries not listed, please contact Server Technology Technical Support. 
Country Codes 
(Approved as of February 2003) 
Country 
Code 
   Result Code 
Country 
Code 
Result Code 
Argentina 34 
52 
Australia 1 
Austria 34 
52 
Belgium 34 
52 
Brazil 34 
52 
Canada 34 
52 
Chile 34 
52 
China 34 
52 
Cyprus 34 
52 
Czech Republic 
25 
37 
Denmark 34 
52 
Estonia 34 
52 
Finland 34 
52 
France 34 
52 
Germany 34 
52 
Greece 34 
52 
Hong Kong 
30 
48 
Hungary 30 
48 
Iceland 34 
52 
India 30 
48 
Indonesia 30 
48 
Ireland 34 
52 
Israel 30 
48 
Italy 34 
52 
Japan 10 
16 
Liechtenstein 34 
52 
Luxembourg 34 
52 
Malaysia 30 
48 
Mexico 34 
52 
Netherlands 34 
52 
New Zealand 
Norway 34 
52 
Philippines 30 
48 
Poland 30 
48
 
Portugal 34 
52 
Russia 34 
52 
Singapore 30 
48 
Slovak Republic 
30 
48 
South Africa* 
35 
53 
South Korea 
34 
52 
Spain 34 
52 
Sweden 34 
52 
Switzerland 34 
52 
Taiwan 34 
52 
Thailand 34 
52 
Turkey 34 
52 
United Kingdom 
34 
52 
United States 
34 
52
*Compliance requires use of an approved surge protection device in conjunction with modem. 
To configure the country code: 
After successfully logging into the modem, type at%t19,0,  followed by the country code and press Enter
Type atz and press Enter to reset the modem with the new settings. 
Example 
The following command sets the modem for compliance in Singapore: 
at%t19,0,30<Enter> 
OK 
atz<Enter> 
OK 
To verify the configured country code: 
Type ati9 and press Enter.  The displayed Result Code should match the code listed in the previous table. 