If a high common-mode voltage is present, connect the negative input pins, 
1 and 3, to the signal reference. Figure 1-5 shows a ground-referenced 
signal connection on one channel of the SCC-AIXX.
 
Figure 1-5.  Ground-Referenced Signal Connection for the SCC-AIXX
with High Common-Mode Voltage (One Channel)
Configuring the SCC System
Measurement & Automation Explorer (MAX) Configuration
Run MAX to configure the SCC system. Complete one of the following 
sets of steps depending on the version of NI-DAQ used in your application.
NI-DAQmx
Complete the following steps to configure the SCC-AI module using 
NI-DAQmx.
1.
Open Measurement & Automation Explorer.
2.
Right-click Devices and Interfaces and select Create New.
3.
Under NI-DAQmx SCC Connector Block select SC-2345. Click 
Finish.
+
4
Lowpass
Filter
+
+
Lowpass
Filter
3
2
1
E Series DAQ Device
Signal
Source
ACH(
)
SCC-AI
XX
AISENSE
AIGND
ACH(
X
+8)
High
CMV
+