NEC PD754244 Manuel D’Utilisation

Page de 306
CHAPTER 11   INSTRUCTION SET
283
User’s Manual  U10676EJ3V0UM
11.4.11  Subroutine/stack control instructions
CALLA !addr1
Function:  (SP–2) 
 
×, ×, MBE, RBE, (SP–3) 
 PC
7-4
(SP–4) 
 PC
3-0
, (SP–5) 
 0, 0, 0, 0
(SP–6) 
 PC
11-8
PC
11-0
 
 addr1, SP 
 SP – 6
CALL !addr
Function: [MkI mode]
(SP–1) 
 PC
7-4
, (SP–2) 
 PC
3-0
(SP–3) 
 MBE, RBE, 0, 0
(SP–4) 
 PC
11-8
, PC
11-0
 
 addr, SP
SP – 4
addr = 0000H to 0FFFH
[MkII mode]
(SP–2) 
 
×, ×, MBE, RBE
(SP–3) 
 PC
7-4
, (SP–4) 
 PC
3-0
(SP–5) 
 0, 0, 0, 0, (SP–6) 
 PC
11-8
PC
11-0
 
 addr, SP 
 SP–6
Saves the contents of the program counter (return address), MBE, and RBE to the data memory (stack) addressed
by the stack pointer (SP), decrements the SP, and then branches to an address specified by 12-bit immediate data
addr.
I/II
II