Tests Run per Test Standard During an Autotest
C
C-3
Table C-1. Tests Run per Test Standard During an Autotest (continued)
Test Standard
1
Attenuation
ACR
Return Loss
Prop.
Delay
2
Delay
Skew
2
TIA Cat 5 Channel
  1-100 MHz
TIA Cat 5 Basic Link
  1-100 MHz
TIA Cat 4 Channel
  1-20 MHz
TIA Cat 4 Basic Link
  1-20 MHz
TIA Cat 3 Channel
  1-16 MHz
TIA Cat 3 Basic Link
  1-16 MHz
Fiber Optic
 (Loss)
ISO11801 EN50173 Class A
 0.1 MHz
ISO11801 EN50173 Class B
 0.1-1 MHz
ISO/IEC11801 Class C
 1-16 MHz
1-16 MHz
ISO/IEC11801 Class D
1-100 MHz
 1-100 MHz
 1-100 MHz
ISO 11801 Class D - No RL
 1-100 MHz
 1-100 MHz
EN 50173 Class C
1-16 MHz
 1-16 MHz
EN 50173 Class D
1-100 MHz
 1-100 MHz
 1-100 MHz
EN 50173 Class D - No RL
 1-100 MHz
1-100 MHz
IEEE 10Base2
IEEE 10Base5
1.
2.
Test standards version 4.0.
Resistance, propagation delay, and delay skew are always measured; results appear on printed test
reports.
Pass/Fail result given.
Pass/Warning result given.
Results within the accuracy specifications of the test tool are marked with an asterisk.
NEXT test is run but not displayed. Results are used to calculate ACR.