Configuring the IP GW
7
Configuring the IP GW
Step one: Log in to the IP GW
All administration of the IP GW is performed through the web interface.
To log in to the web interface of the IP GW:
1
Use your browser to navigate to the IP address of the IP GW (to discover the IP 
address, refer to the previous section).
2
Click 
Click here to log in
, and then click
 Change log in
 and enter the user name 
admin
 with no password. 
Step two: Configure Ethernet Port B settings (optional)
Port B is configured through the web interface.
The default setting for the IP GW Ethernet ports is auto-sensing mode. If the switch 
ports to which you connect the IP GW are not also set to auto-sensing mode, then 
you need to configure the IP GW Ethernet ports to use the same speed and duplex 
mode.
1
To configure Ethernet Port B, go to 
Network > Port B
2
Enter the IP address, subnet mask, default gateway and DNS name server for the 
port.
3
Enter a secondary name server and domain name if required.
4
Click 
Update IP configuration
.
Codian recommends that you change the admin account to use a 
password as soon as possible. To do that, go to 
Users
, click the 
admin
 
link, and provide the required user information.
Both ends of the Ethernet connection must be configured in the same 
way. For example, either configure both ends of the link to be auto-
sensing or configure both ends to operate at the same speed and duplex.
To establish a 1000Mbps connection, both ends of the link must be 
configured as auto-sensing.