Emerson FM-3 Manuel D’Utilisation

Page de 292
37
Setting Up Parameters
Foldback RMS
This parameter accurately models the thermal heating and cooling of the drive and motor. 
When it reaches 100 percent, current foldback will be activated. See the Diagnostics section 
for an explanation of foldback.
Shunt Power RMS
This parameter models the thermal heating and cooling of the drive internal shunt. This 
parameter indicates the percent of shunt capacity utilization. When this value reaches 100 
percent, the drive will generate an RMS Shunt Power Fault. This parameter is not applicable 
to the EN-204 which does not have an internal shunt resistor. This parameter is applicable to 
the EN-208 and EN-214.
Information Tab (Online Only)
Drive Information Group
Firmware Part Number
Displays the part number of the drive firmware you are using.
Firmware Revision
Displays the revision of the drive firmware you are using.
Serial Number
Displays the serial number of the drive with which you are currently online.
Module Information Group
Firmware Part Number
Displays the part number of the FM-3 firmware you are using.
Firmware Revision
Displays the revision of the firmware in the FM-3 module with which you are currently 
online.
Serial Number
Displays the serial number of the FM-3 module with which you are currently online.