Chapter 5  Troubleshooting and Diagnostics 
RIC-155 Installation and Operation Manual 
5-8 Handling 
Alarms
 
 
An alarm or warning enters simultaneously both the alarms display and the log file, 
and the ALM LED turns on to indicate the condition. When the fault condition that 
caused the alarm is cleared, the alarm is removed from the alarm screen, but it 
remains in the log file, enabling you to view the alarm history.  
Events enter only the log file.  
The RIC-155 management software allows you to change alarm severity and 
perform alarm masking. 
Displaying System Alarms 
 
To display the system alarms: 
1.  From the Main menu, select Monitoring
2.  From the Monitoring menu, select System Monitoring
The System Monitoring menu appears (see 
RIC-155 
System Monitoring 
System Status  
  > 
System Alarms  
  []> 
Event Log 
 
  []> 
Clear Event Log 
 

ESC-prev.menu; !-main menu; &-exit;  
Figure 5-9.  System Monitoring Menu 
3. Select System Alarms to display the system alarms. 
The System Alarms screen appears (see 
RIC-155 
System Alarms  
 
  Code       Name                                State    
   1         Self-test failure                   Major 
   2         Line Excessive Error Defect         Major 
   3         Line Signal Degraded Error          Minor 
   4         Loss Of Signal                      Major 
   5         Loss Of Frame                       Major 
ESC-prev.menu; !-main menu; &-exit;  
Figure 5-10.  System Alarms Screen 
Working with the Log File 
RIC-155 maintains alarm log files for system alarms. The file stores up to 200 alarm 
messages. The log file specifies alarm or event name, state (major, minor, or OFF), 
and time when the alarm was initiated. OFF indicates that the fault condition that 
caused the alarm is cleared. 
 
To display the event log file: 
•  From the System Monitoring menu (
), select Event Log