RAD Data comm RIC-155 Manuel D’Utilisation

Page de 90
RIC-155 Installation and Operation Manual 
Chapter 5  Troubleshooting and Diagnostics 
 
Handling Alarms 
5-9 
The Event Log screen appears (
Figure 5-11
). 
RIC-155 
Event Log 
 
     Source Alarm                        Status  Severity  Time      Date 
  4  Event  Loss Of Signal               ON      Major     2:11:13   12/06/03 
  5         Loss Of Frame                ON      Major     3:52:31   13/06/03 
| 3         Line Signal Degraded Error   OFF     Minor     13:45:27  13/06/03 
V 16        Software download            OFF     Warning   14:52:17  13/06/03 
  2         Line Excessive Error Defect  ON      Major     20:46:02  13/06/03 
 54         Buffer Overflow              OFF     Event     9:13:20   14/06/03 
ESC-prev.menu; !-main menu; &-exit;  
Figure 5-11.  Event Log Screen 
 
To clear the event log: 
1.  From the System Monitoring menu (
), select Clear Event Log
RIC-155 displays a confirmation message at the bottom of the screen:  
Request to clear log file! Are you sure? (Y/N): 
2. Type Y
All the log file entries are deleted from the system log file. 
Configuring Alarm Severity 
Severity of the RIC-155 alarms can be defined by the user. Configuration of the 
alarm severity is performed via the System Alarms menu. 
 
To configure the alarm severity: 
1.  From the System Configuration menu, select Alarm Configuration
The Alarm Configuration menu appears (
RIC-155 
Alarm Configuration 
System Alarms  
  []> 
Default Alarms Setting 
   
 
 

Please select item <1 to 2> 
ESC-prev.menu; !-main menu; &-exit;  
Figure 5-12.  Alarm Configuration Menu 
2.  From the Alarm Configuration menu, select System Alarms
System Alarms menu appears (
3.  From the System Alarms menu, select Severity column of the alarm that you 
intend to configure by moving cursor up/down or left/right. 
4.  Select a new alarm severity value by typing 1 (Minor) or 2 (Major).