RAD Data comm RIC-155 Manuel D’Utilisation

Page de 90
Appendix B  Traffic Separation 
RIC-155 Installation and Operation Manual 
B-4 
Port-Based/VLAN-Based Traffic Separation 
 
Internal Operation Modes of the Bridge Ports 
All VLAN information is kept in the VTU (VLAN Translation Unit) table. The bridge 
ports operate in the following internal modes: 
•  Secure – only frames with VIDs that are registered in the VTU table are 
forwarded according to the VTU rules. The management and host ports 
operate in the secure mode only. 
•  Fallback – untagged frames and tagged frames with VIDs that are not 
registered in the VTU table are forwarded according to the port-based 
procedures only. 
The internal port operation modes depend on the port access mode and 
forwarding mode of the bridge, as detailed in 
Table B-2.  Internal Port Operation Modes 
Forwarding Mode 
Filter Tagged 
Management Access Mode 
Port 
Filter 
None MNG 
Only 
All Local 
MNG 
Only 
MNG Disabled 
Secure 
Secure 
Secure 
Data 
Fallback Fallback Fallback  Fallback 
Host 
Secure Secure Secure  Secure 
Uplink 
Disabled 
Fallback Fallback Fallback  Fallback 
Traffic Separation according to the Management Access and VLANs 
The following diagrams illustrate how RIC-155 separates between the management 
and user traffic according to the port access mode and bridge port VLANs 
(management port VID is set to 1, data port VID is set to 2). Numbers 1 and 2 inside 
the bridge indicate the management and data frame routes inside the bridge. 
None 
When the port access mode is set to None, the management port is disabled. 
Frames coming from the local data port can reach the local uplink port only, and 
remote data frames can reach the local data port only. Remote management 
frames are forwarded to the local host port only. 
In the None access mode, the host port checks the source port of the incoming 
frames and drops those that do not originate from the management port.