RAD Data comm RIC-155 Manuel D’Utilisation

Page de 90
RIC-155 Installation and Operation Manual 
Appendix B  Traffic Separation 
 
Port-Based/VLAN-Based Traffic Separation 
B-5 
MNG
Host
Uplink
Data
Secure
Secure
Fallback
Tag Stripping Enabled
Fallback
Stack
 
Figure B-5.  Port Access Mode – None 
MNG Only 
In the MNG Only port access mode, local data frames can reach the uplink port 
only. Local management frames can reach the host and uplink ports, and the 
remote management frames can reach the local uplink, host and data ports. 
In the MNG Only access mode, the host port checks the source port of the 
incoming frames and drops those that do not originate from the management port.  
See 
 for the application example. 
MNG
Host
Uplink
Data
Secure
Secure
Fallback
Tag Stripping Enabled
Fallback
Stack
 
Figure B-6.  Port Access Mode –MNG Only 
All 
In the All port access mode, data and management frames can reach all ports, 
allowing management of the local and remote units via the MNG and DATA ports. 
If the units are going to be managed via the DATA port, it is necessary to add 
VLAN tags to the frames before they enter RIC-155. This can be done by an 
external device, such as a switch. In this case the host must be configured to tag 
the incoming management frames according to the setting of the external switch. 
See 
 for the application example. 
MNG
Host
Uplink
Data
Secure
Secure
Fallback
Tag Stripping Disabled
Fallback
Tag
 
Figure B-7.  Port Access Mode – All