Appendix E  Parameters and Screens 
 
IPmux-1 E1/T1 Configuration 
E-19 
Table E-12.  T1 Configuration Parameters (Cont.) 
Parameter Possible 
Values 
Remarks 
Restore Time 
1 second,  
10 seconds
 
Selects the T1 red alarm recovery time 
Default value: 1 second 
Idle Code 
00
 to FF 
Inserted into unused timeslots by IPmux-1 at the transmit path 
towards T1 equipment 
Note: This field will not appear if “unframed” is selected in the 
Line Type field. 
Default value: 7E 
Signaling Mode 
CAS enable 
 
CAS disable 
T1 framer is set to CAS mode and the operation mode to 
Fractional with CAS mode 
CAS mode will not be set in the T1 framer and the operation 
mode will be configured to Fractional mode 
Note: This field will not appear if “Unframed” is selected in the 
Line Type field.
 
Default value: CAS Enable 
Cond. data pattern 
00
 to FF 
Byte Code applied to timeslots when fault conditions occur 
Conditioning pattern can be applied to timeslots toward the IP 
path when loss of signal, loss of frame or AIS detected at the 
T1 line. Conditioning pattern can also be applied to timeslots 
toward the T1 line when packet receive buffer overrun or 
under-run occurs. In Unframed mode, conditioning state 
results in AIS transmission. This is applied when a LOS is 
detected at T1 line, or when packet receive buffer overrun or 
under run occurs. 
Note: This field will not appear if “Unframed” is selected in the 
Channel Type field.
 
Default value: 7F 
Cond CAS (ABCD) 
pattern 
to F 
2 or 4 Bit Code applied to AB(D4) or ABCD (ESF) bits when 
fault conditions occur 
The ABCD conditioning pattern can be applied toward the IP 
path when loss of signal, loss of frame or AIS detected at the 
T1 line. Conditioning pattern can also be applied toward the 
T1 line when packet receive buffer overrun or under run 
occur. 
Note: This field will not appear if “Unframed” is selected in the 
Channel Type field.
 
Default value:  1 