Appendix E  Parameters and Screens 
IPmux-1/1E Installation and Operation Manual 
E-20 
IPmux-1E ISDN Configuration 
 
Table E-12.  T1 Configuration Parameters (Cont.) 
Parameter Possible 
Values 
Remarks 
Cond. CAS first 2.5 sec 
pattern 
0
 to F (ESF) 
0
 to 3 (D4) 
FF 
2 or 4 Bit Code applied (during the first 2.5 seconds) to 
AB(D4) or ABCD (ESF) bits (relevant in CAS mode only) when 
fault conditions occur. After the first 2.5 seconds the code 
specified in ‘Cond. CAS (ABCD) pattern’ is applied. ABCD 
conditioning pattern can be applied toward the IP path when 
loss of signal, loss of frame or AIS detected at the T1 line. 
Conditioning pattern can also be applied toward the T1 line 
when packet receive buffer overrun or underrun occurs. 
When configuring FF to this function, this parameter is ignored 
and the CAS pattern applied in the first 2.5 seconds is the 
same as defined in ‘ Cond. CAS (ABCD) pattern’.  
Note: This field does not appear if “unframed” is selected in 
the Line Type field or if CAS Disable is selected. 
Default value: FF 
 
E.5  IPmux-1E ISDN Configuration 
ISDN CONFIGURATION 
1. Interfaces Mode 
Terminal 
2. Transmit Clock Source 
Adaptive 
3. Channel Configuration 
ESC. Exit 
 
Select item from the menu. 
Figure E-21.  ISDN Configuration Menu 
Main Menu 
         ↓ 
2. Configuration 
         ↓  
2. ISDN 
Configuration 