RAD Data comm IPmux-1E Manuel D’Utilisation

Page de 143
Chapter 1  Introduction 
IPmux-1/1E Installation and Operation Manual 
1-12  
 
Functional Description
 
 
IPmux-4/16
IPmux-1
IPmux-1
IPmux-1
E1/T1 Line 1
E1/T1 Line 2
E1/T1 Line 4
E1/T1 Line 3
IPmux-1
Sub E1/T1
Sub E1/T1
Sub E1/T1
Sub E1/T1
IP over 
Ethernet
 
Figure 1-10.  Grooming of Timeslots from Remote Sites into a  
Single E1/T1 Port at Central Site 
Other BRI/FXS applications are shown in Figure 1-3Figure 1-4, and Figure 1-5.  
Operation Modes 
IPmux-1 E1/T1  
IPmux-1 E1/T1 operation modes are: 
•  Unframed 
•  Fractional 
•  Fractional with CAS. 
Unframed 
In the transparent mode, the incoming bit stream from each channel (regardless of 
framing) is converted into IP over Ethernet frames. This option provides clear 
channel end-to-end service (unframed).  
Fractional 
In the fractional mode, the incoming bit stream is regarded as a sequence of  
n x 64 kbps channel groups (according to framing). Each predefined group of 
channels is converted into a structure block. The structure block is packetized into 
IP frames and transmitted.  
This mode allows transmission of several selected timeslots without the whole E1 
or T1 frame, as in transparent mode. 
 
 
Use Fractional mode when grooming ISDN BRI channels from a remote IPmux-1E 
unit. 
 
Note 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com