Chapter 1  Introduction 
 
Functional Description 
1-13 
Fractional with CAS 
In the fractional-with-CAS mode, the structure block (as described under 
Fractional Operation Modes, above) also includes Channel Associated Signaling 
(CAS). The relevant portion of the signaling channel is packetized and sent to the 
destination.  
 
 
Use Fractional with CAS mode when grooming FXS channels from a remote  
IPmux-1E unit. 
 
 
IPmux-1E ISDN BRI  
The IPmux-1E ISDN BRI S interface operation modes are: 
•  TE mode 
•  NT mode. 
The selected mode applies to all 4 channels. The NT or TE mode is determined by 
phantom feeding and software setting, which is enabled/disabled by jumpers 
located on the BRI card (see Chapter 2). 
TE Mode 
All four channels are configured in TE (Terminal Equipment) as defined in I.430. 
NT Mode 
All four channels are configured in NT (Network Termination) as defined in I.430. 
TE Deactivation is not used in NT mode, and Layer 1 is in active mode all the 
time. 
 
 
If phantom feeding is enabled by the jumpers, the TE mode cannot be selected as 
the IPmux-1E operation mode. If phantom feeding is disabled, both NT and TE are 
valid options. 
 
IPmux-1E FXS  
IPmux-1E FXS operates in: 
•  E1 mode 
•  T1-D4 mode 
•  T1 ESF mode. 
Note 
Note 