RAD Data comm IPmux-1 Manuel D’Utilisation

Page de 143
Appendix E  Parameters and Screens 
IPmux-1/1E Installation and Operation Manual 
E-16 
IPmux-1 E1/T1 Configuration 
 
Table E-11.  E1 Physical Layer Configuration Parameters (Cont.) 
Parameter Possible 
Values 
Remarks 
Signaling mode 
CAS enable 
 
CAS disable 
The E1 framer is set to CAS MF mode and the operation mode 
to fractional with CAS mode. 
CAS MF will not be set in the E1 framer and the operation 
mode will be configured to fractional mode. 
Note: This field will not appear if “unframed” is selected in the 
Line Type field. 
Default value: CAS Enable 
Byte Code 
00
 to FF 
Conditioning pattern can be applied to timeslots toward the IP 
path when loss of signal, loss of frame or AIS is detected at the 
E1 line. Conditioning pattern can also be applied to timeslots 
toward the E1 line when packet receive buffer overrun or 
under-run occurs. In Unframed mode, conditioning state will 
result in AIS transmission. This will be applied when a LOS is 
detected at E1 line, or when packet receive buffer overrun or 
under run occurs. 
Note: This field will not appear if “unframed” is selected in the 
Channel Type field. 
Default Value: FF 
4 bit code 
1
 to 
The ABCD conditioning pattern can be applied toward the IP 
path when loss of signal, loss of frame, or AIS is detected at the 
E1 line. Conditioning pattern can also be applied toward the 
E1 line when packet receive buffer overrun or underrun occur. 
Note: This field will not appear if “Unframed” is selected in the 
Channel Type field. 
Default Value:  1 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com