RAD Data comm IPmux-1 Manuel D’Utilisation

Page de 143
Appendix E  Parameters and Screens 
IPmux-1/1E Installation and Operation Manual 
E-18 
IPmux-1 E1/T1 Configuration 
 
Table E-12.  T1 Configuration Parameters 
Parameter Possible 
Values 
Remarks 
Channel Status 
Enable 
Disable
 
Detection of LOS alarm 
No detection of LOS alarm 
Default value: Enable 
Transmit Clock Source 
Adaptive 
Loopback 
 
Internal
 
Adaptive clock regeneration 
T1 recovered receive clock is used as the transmit 
clock. 
Local clock source is used. 
Default value: Adaptive 
Loopback State 
Internal 
 
 
 
External 
 
 
 
Disable 
Data received from the IP network side will be looped 
back to the network transmit line. An unframed all ‘1’ 
code (AIS) will be transmitted in the T1 Tx path toward 
the PBX. Incoming data from the PBX will be ignored. 
Data received from the PBX at the receive T1 line will 
be looped back to the T1 Tx path (toward the same 
PBX), and will continue its way to the IP network. Data 
coming from the IP network will be ignored. 
No loopback. Regular operation. 
Default value: Disable 
Line Type 
 
 
T1-D4 
 
 
T1-ESF 
 
 
Unframed 
Framing mode and operation mode for each 
configuration: 
Framer will be configured to T1-D4 mode. Operation 
mode will be set by Signaling mode field #6 to either 
Fractional or Fractional with CAS (see Chapter 1). 
Framer will be configured to T1-ESF mode. Operation 
mode will be set by signaling mode field #6 to either 
Fractional or Fractional with CAS (see Chapter 1). 
Framer will be configured to pass through mode and 
the operation mode will be set to unframed (see 
Chapter 1). 
Default value: T1-ESF 
Line Code 
B7ZS, B8ZS, AMI 
Default value: B8ZS 
Line Mode 
DSU, CSU 
Default value: DSU 
Line Length / Tx Gain 
DSU: 0-133, 134-266,  
267-399, 400-533,  
534-655 
CSU: 0 dB, –7.5 dB,  
–15 dB, –22.5 dB
 
Default value: 0-133 ft 
 
 
 
 
Default value: 0 dB 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com