RAD Data comm IPmux-1 Manuel D’Utilisation

Page de 143
Appendix E  Parameters and Screens 
IPmux-1/1E Installation and Operation Manual 
E-30 Performance 
Monitoring 
 
Table E-21.  E1/T1 Statistics Parameters 
Alarm Failure Comments 
LOS 
Loss of Signal 
Sync LED Off 
•  For T1: A second during which 192 contiguous pulse positions have no 
pulse of either positive or negative polarity (signal is more than 30 dB 
below nominal amplitude. 
•  For E1: A second during which 255 contiguous pulse positions have no 
pulse of either positive or negative polarity. 
LOF 
Loss of Frame  Sync LED Off 
•  For E1/T1: A second during which an OOF (see below) error persists for 
2.5 seconds and no AIS error (see below) is detected. 
LCV Line 
Code 
Violation 
Line Code Violation 
•  For T1: A second during which BPV (Bipolar Violation) or EXZ errors have 
occurred. 
•  For E1: A second during which two consecutive BPVs of the same polarity 
are received. 
BPV is the occurrence of a pulse with the same polarity as the previous 
pulse. 
EXZ is the occurrence of a zero string greater than 15 for AMI or 7 for B8ZS. 
Complies with ITU-TI.431, 0.161, G.775 and G.821 standards. 
Rcv RAI  
(Yellow 
Alarm)  
Remote 
Alarm 
Indication 
Sync LED flashes 
•  For E1/T1, a second during which tan RAI pattern is received from the far 
end when the far-end framer enters a RED state (Loss of Frame). 
AIS Alarm 
Indication 
Signal–
Received 
from User 
Sync LED is Off 
•  For T1: A second during which an unframed “all 1” signal is received for 
3 milliseconds. 
•  For E1: A second during which a string of 512 bits contains fewer than 
three zero (0) bits. 
FEBE 
Far End Block 
Error 
Number of seconds in which the FEBE indication is received from the 
remote E1 device.  
•  For E1 MF-CRC4 only 
BES Bursty 
Errored 
Seconds 
(Errored 
Second type 
B) 
Number of seconds with from two to 319 CRC error events with no AIS nor 
SEF (Framing Bit Errors) error detection 
Complies with AT&T TR-62411 and TR-54016 standards. 
Not applicable if Line Type is set to Unframed  
T1-ESF or E1-CRC4 modes 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com