Drive operation and maintenance 
Page 22 
Seagate Travan 40 Product Manual 
DRAM Write Miscompare 
DRAM Write Timed Out 
DRAM Read Timed Out 
DMA Timed Out 
ATAPI Interface Failed 
SRAM Self Test Failed 
DRAM/SRAM Self Test Failed 
Serial ASIC Failed 
Buffer Manager ASIC Failed 
11 
Stepper Motor Test Failed 
12 
Transport Motor Test Failed 
15 
Attempt to install incompatible firmware 
16 
Transfer timeout 
17 
Load operation failed 
Drive does not come ready 
• 
Insure the cartridge is properly oriented and fully inserted. 
• 
Insure the cartridge is not broken and the tape appears in good condition. 
Motor starts to drive cartridge but stops immediately 
Check the cartridge for tape run-off, or excessive torque. Replace cartridge if 
required. 
Drive will not write but will read previously written tapes 
• 
Make sure the cartridge is not write-protected. 
• 
Make sure the cartridge is a Travan 40 cartridge, not a Travan 5 or older Travan 
cartridge. 
• 
Verify proper cable attachment to the host PC. 
• 
If this does not correct the problem, contact Seagate Technical Support (see 
page 21). 
Tape does not stream 
Host data handshake may be too slow. Check BIOS setting for ATAPI interface 
mode; the interface chipset may not be capable of high speed PIO mode. Some 
backup application software is capable of higher transfer rates than others. Other 
Host activity could restrict backup operation transfer rate. 
If a power interruption occurs during a backup or restore operation, start over when 
the power is restored.