CHAPTER 10 CONFIGURATION TOOL
10
10.3  Par
ameters
10.3.2 
 CC-Link IE Field Networ
k
(1) CC-Link IE Field Network gateway setting
When the network address (the first and second octets of the IP address) of the external device is different from 
that of the master station, set the communication route where communications reach the request destination 
external device.
This setting is not required when the request source external device, request destination external device, and 
modules between them have the same network address. 
Configure the CC-Link IE Field Network gateway setting to perform IP communications via CC-Link IE Field 
Network (IP packet transfer function). (
If the setting is configured although the network address of the external device is the same as that of the master station, the 
Ethernet adapter module ignores the setting.
(a) Setting details
Setting item tree 
 NZ2GF-ETB 
 [Parameter] 
 "CC-Link IE Field Network Gateway Setting" 
 button
The following table lists the setting items on the dialog box.
Item
Description
Setting range
IP Address Input Format
Set the input type for the IP address and subnet mask pattern.
DEC/HEX
(Default: DEC)
192   .  168     .    3    .    1
Network address