ZyXEL Communications 650 Series Manuel D’Utilisation

Page de 513
Prestige 650 Series User’s Guide 
33-4  
SNMP 
Configuration 
33.4  SNMP Traps  
The Prestige will send traps to the SNMP manager when any one of the following events occurs: 
Table 33-2 SNMP Traps 
TRAP # 
TRAP NAME 
DESCRIPTION 
1 coldStart 
(defined in RFC-1215
A trap is sent after booting (power on). 
2 warmStart 
(defined in RFC-1215
A trap is sent after booting (software reboot). 
3 linkDown 
(defined in RFC-1215
A trap is sent when the port is down. 
4 linkUp 
(defined in RFC-1215
A trap is sent when the port is up. 
5 authenticationFailure 
(defined in 
RFC-1215
A trap is sent to the manager when receiving any SNMP 
get or set requirements with wrong community (password). 
whyReboot (defined in ZYXEL-
MIB) 
A trap is sent with the reason of restart before rebooting 
when the system is going to restart (warm start). 
6a 
For intentional reboot : 
A trap is sent with the message "System reboot by user!" if 
reboot is done intentionally, (for example, download new 
files, CI command "sys reboot", etc.). 
The following table maps the physical port and encapsulation to the interface type. 
Table 33-3 Ports and Interface Types 
PHYSICAL PORT/ENCAP 
INTERFACE TYPE 
LAN port(s)  
enet0 
Wireless port 
enet1      
PPPoE encap 
pppoe 
1483 encap 
mpoa 
Ethernet encap 
enet-encap 
PPPoA               
ppp