 H2TU-C-319 List 4E
A3LB and A4LB Test Procedures
The H2TU-C can be looped back by sending the Addressable Office Repeater (AOR) LPBK activation code 
1111-1111-0001-1110 (FF1E) for at least 5 seconds. This causes the H2TU-C to enter the NLOC state. The 
Loopback Time-out setting (see 
) determines the duration of 
this loopback unless it is overridden by the reception of a second identical 16-bit loopup command before the timer 
expires. When this time-out override state exists, the only way to loop the H2TU-C down is to issue one of the 
three loopdown commands listed in 
. The automatic time-out mode is restored during subsequent 
loopback sessions.
 summarizes the codes required to execute Addressable 3 and 4 (A3LB and A4LB) repeater loopback 
commands that are identified in H2TU-C HDSL2 products. All code sequences must be present for at least 5 
seconds. Information specific to HiGain HDSL2 regenerators is shown in bold. 
SmartJack Test Procedure
The HiGain H2TU-R supports the standard SmartJack loopback which can emulate a Network Interface Device 
(NID) for the purpose of loopback testing of the HiGain HDSL2 circuit. SMJK and NREM loopbacks perform the 
same functions, but their initiation differs. SMJK indicates that the loopback was initiated by any of the three 
SmartJack loopup commands listed in 
. NREM, on the other hand, is initiated by the 3-in-7 in-band 
command or by a command issued from the maintenance terminal.
The SmartJack loopback option, LPBK, enables or disables the ability of the H2TU-R to emulate the family of 
SmartJack loopback commands listed in 
Table 24.
Addressable Repeater Loopback Commands (A3LB and A4LB)
Name
Description
Binary Code
 (a)
 (Hexadecimal Equivalent)
(a) The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10
-3
 Bit Error Ratio (BER) 
on the facility. The entire loopback sequence can also be initiated at the remote H2TU-R location.
NLOC
H2TU-C loopup from NI
1111-1111-0001-1110 (FF1E)
CREM
H2TU-C loopup from CI 
0011-1111-0001-1110 (3F1E)
NREM
H2TU-R loopup from NI
1111-1111-0000-0010 (FF02)
CLOC
H2TU-R loopup from CI
0011-1111-0000-0010 (3F02)
Table 25.
SmartJack Loopup and Loopdown Commands
In-Band 2-in-5 
Loopup Code
In-Band 3-in-5 
Loopdown Code 
Out-of-Band 
ESF-FDL Loopup 
Codes
Out-of-Band 
ESF-FDL Loopdown 
Codes 
 (a)
(a) These universal loopdown codes can release any and all existing loopup states regardless of loopback direction or method of 
initiation. The codes are permanently enabled and independent of all loopback option settings, including the LPBK option.
In-Band 1-in-6 
Loopup Code
In-Band 1-in-3 
Loopdown Code
11000
111000
1111-111-0100- 1000 1111-1111-0010-0100 100000
100