ADC H2TU-C-319 List 4E Manuel D’Utilisation

Page de 88
LTPH-UM-1049-02, Issue 2
 
Appendix A - Specifications
H2TU-C-319 List 4E
January 9, 2002
 65
A
PPENDIX
 A - S
PECIFICATIONS
Power
HDSL2 Span Voltage
0 or -180 ±5 Vdc
CO Supply
-48 Vdc nominal (-42.5 Vdc to -56.5 Vdc) 
 and 
Electrical Protection
Secondary surge and power cross protection on HDSL2 ports. Requires external 
primary protection.
Fusing
Internal; connected to “FUSE ALARM” output on pin 10
Environmental
Operating Temperature
-40°F to +149°F (-40°C to +65°C)
Operating Humidity
5% to 95% (non-condensing)
Physical
Height
4.750 in. (12.10 cm)
Width
0.625 in. (1.59 cm)
Depth
10 in. (25.4 cm)
Weight
0.5 lb (.23 kg)
Mounting
3192 mechanics shelf
HDSL2
Line Code
1.552 Mbps OPTIS
Transmission
Full duplex
Media
One non-loaded, copper, two-wire cable pair
Output
+13.8 dBm ±0.5 dB at 135
Ω 
(0-450 kHz)
 
at CO side; 
+13.5 dBm ±0.5 dB at 135
Ω 
(0-350 kHz) at remote side
Line Impedance
135
Ω
Maximum Provisioning Loss
35 dB at 196 kHz
Start-up Time
30 sec. typical, 1 min. maximum per span
DSX-1
DSX-1 Line Impedance
100
Ω
DSX-1 Pulse Output
6 V
pk-pk
 pre-equalized for 0-655 feet of ABAM cable
DSX-1 Input Level
+1.5 to -7.5 dB DSX
System
One-way DS1 Delay
<400 µs per span without regenerators
Wander (Looped)
Meets MTIE T1.101 requirements
Wideband Jitter (Looped)
0.2 UI maximum
Narrowband Jitter (Looped)
0.1 UI maximum